Kinetics Chemistry
Student Name:Saba Ahmad Bin Humaid
Supervisor:Dr. Alia Abdulaziz Alfi
Group Number: 41438-1439
Spectrophotometry is a technique which can be used for identifying reactants’ concentrations.Spectrophotometry is an absorbance device which can measures the fraction of the incident light transmitted through a solution. More clearly, it is used to measure the amount of light that passes through particles of the sample and by differentiation of the initial intensity of light reaching the sample, it indirectly measures the amount of light absorbed by that sample.
Spectrophotometers are made to transmit light of narrow wavelength ranges. A certain compound will not absorb all wavelengths evenly that’s why things have different colours. Some compounds absorb only wavelengths outside of the visible light spectrum and that’s why there are colourless solutions such as water. Because different compounds absorb light at different wavelengths, a spectrophotometer can be used to differentiate compounds by analyzing the type of wavelengths absorbed by a given sample.
In addition of that, the amount of light absorbed is directly proportional to the concentration of absorbing compounds in that sample, so a spectrophotometer can also be used to determine concentrations of compounds in solution.To studying a compound in solution by spectrophotometry, you put it in a sample holder called a cuvette and place it in the spectrophotometer.
Light of a specific wavelength passes through the solution inside the cuvette and the amount of light transmitted or absorbed by the solution is measured by a light meter. While a spectrophotometer can exhibit measurements as either transmittance or absorbance, in biological applications we are usually interested in the absorbance of a given sample. Because other compounds in a solution (or the solvent itself) may absorb the same wavelengths as the compound being analysed, we compare the absorbance of our test solution to a reference blank.
The reference blank should contain everything found in the sample solution except the substance you are trying to analyse or measure.Briefly,-5143507591425003467100758190000 you can determine the unknown concentration of the sample by using Beer Lambert Law which states: there is a linear relationship between the absorbance and the concentration of a sample.
Mathematical formula of Beer’s Law is: A=?lcWhere:A is the measure of absorbance.? is the molar extinction coefficient or molar absorptivity.l is the path length.c is the concentration (which is required).There are special techniques for investigating fast reactions which have half-live less than a few secondsLet us take an example for the simplest fast reaction technique (the continuous flow method) which will be used to study the kinetics of the formation of the ferric thiocyanate complex FeSCN+22120900145742100
For the fast reaction between ferric and thiocyanate ions in an acid solution of constant pH, the observed behavior is consistent with the simple mechanism: center2191301Where kf is the bimolecular forward rate constant and kr is the unimolecular reverse rate constant. So, the rate law from this equation is:center27279960
Recall that the equilibrium constant K is related to the rate constant by:15775923297435Where the sign ? means the equilibrium (t=?) value:31439213903453641206384715300At any time (t), Using these relations, and then rewrite the equation in the form:1965852489141700To simplify the integration of this equation, we will choose the experimental conditions such that [Fe+3] ;; [SCN-]. This will allow us to assume that [Fe+3] is essentially constant during the reaction.
The initial conditions are chosen so that [FeSCN+2]0= at t=0 we find:This an approximate solution which becomes exact only when [Fe+3] is constant. In real practice, [Fe+3]0 will be chosen to be ten times larger than [SCN-]0, so that [Fe+3] will be more by about 10 percent during the reaction.2803525690943500-569595690918400If a plot of ln](FeSCN+2)? – (FeSCN+2)[ versus t is linear, then the first order dependence on [SCN-] and [FeSCN+2] is confirmed.
The rate dependence on [Fe+3] has been established as first order. -5779714625Schematic diagram of system for driving reactant solution.00Schematic diagram of system for driving reactant solution.452856889798Spectrophotometry setup00Spectrophotometry setupProcedure for an example of use Spectrophotometer technique in fast reaction: Firstly, turn on the spectrophotometer and leave it warm up before using.
The wavelength setting should be 455 nm throughout the entire experiment. With both reagent stopcocks A and B and the vent stopcock V closed, slowly increase the gas pressure on the reagent solutions until Bourdon pressure gauge indicates about 500 Torr pressures above 1 atm. With the outlet stopcock C open, open and close the reagent stopcocks A and B several times to make sure that both solutions are flowing smoothly and to remove any air bubbles from the system.
Use a beaker to catch the outflow from the capillary tube. Then set the capillary frame at the first fiducial mark which nearest to the mixing chamber, and carry out the three following steps:1- Open Stopcock A and allow the Fe+3 solution to flow for a sufficient time to remove from the capillary tube any solution containing FeSCN+2 species.
Then close stopcock A and the outlet stopcock C.2- Open the outlet stopcock C then turn both stopcocks A and B to their fully open positions. Catch the outflow of solution from the capillary in a beaker until the flow becomes stable. Then quickly switch the outlet tube from the beaker to a volumetric flask and simultaneously start a timer.
When It is full, stop the timer and record the time. Return the outlet tube to the beaker. Then carrying out the above flow rate measurement, you should determine the absorbance A of the reaction mixture and record that value together with the distance x from the mixing chamber. Work quickly to avoid any interference of the reagent solution.
3- When both the flow and absorbance measurements are complete, close the outlet stopcock C and then close both stopcock A and B. This is a crucial step in the procedure. If A and B are left open, solution may siphon from one carboy to the other. After a few minutes, determine the absorbance again to obtain the infinite time value.
Verify that this value does not change after one more minute.For the next run, move the capillary support frame so as to line up the second fiducial mark and repeat the first and third steps at this this new distance setting, be careful in moving the capillary support frame.Make two runs at each of the six or seven positions along the capillary tube. Use special care in making the absorbance readings at large values of x. If time permits, you should also take data at a different driving pressure.
Either increase or decrease the gas pressure depending on weather you need more data at low percent reaction or at high, but it may not be safe to exceed about 700 torr overpressures.In this experiment, more of solution A will be used up than solution B if the Fe+3 solution is always used in the first step to make the zero adjustment of the spectrophotometer at each distance setting.
The resulting change in the liquid level for A relative to that for solution B may change the relative flow rates of these solutions. This can be avoided by alternating the use of solution A and B for making the zero adjustments.References:1- Physical chemistry by Gilbert William Castellan.2- msu.edu.3- Wiley online library. 4- UKessay.5- AliHayek.com
You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.
Read moreEach paper is composed from scratch, according to your instructions. It is then checked by our plagiarism-detection software. There is no gap where plagiarism could squeeze in.
Read moreThanks to our free revisions, there is no way for you to be unsatisfied. We will work on your paper until you are completely happy with the result.
Read moreYour email is safe, as we store it according to international data protection rules. Your bank details are secure, as we use only reliable payment systems.
Read moreBy sending us your money, you buy the service we provide. Check out our terms and conditions if you prefer business talks to be laid out in official language.
Read more