Persistence of DNA: An examination of degradation of blood sourced DNA on knives, by household substances and the forensic implications
A review of relevant and current peer-reviewed literature
Contents (Jump to)
Phenolphthalein and Leucomalachite
Figures
Figure 1. Incidence of homicide victims and accused 2003-2013
Tables
Table 1. Homicide figures and methods of killing from 2003-2013
Table 2. Homicide methods in Lothian and Borders 2006-11
Abbreviations
CODIS – Combined DNA index system
DNA – Deoxyribonucleic acid
LCN – Low copy number
LMG – Leucomalachite green
PCR – Polymerase chain reaction
qPCR – Real time Polymerase chain reaction
RFLP –Restriction fragment length polymorphisns
SGM – Second generation multiplex
STR – Short tandem repeat
Often after an assault with a weapon, i.e. a stabbing or murder, attempts are made to clean and or dispose of the weapon used. The most readily available weapon is a knife, whether the attack is pre-planned or ‘spur of the moment’, knifes are easily available to buy and are also, part and parcel with every household i.e. kitchen.
Incidences of homicide in Scotland are at the lowest point for ten years, having dropped from 109 in 2003 to 62 in 2013, as seen in Figure 1.
Fig 1. Incidence of homicide victims and accused 2003-2013 (ScotGov, 2013)
Main method of killing |
2003-04 |
2004-05 |
2005-06 |
2006-07 |
2007-08 |
2008-09 |
2009-10 |
2010-11 |
2011-12 |
2012-13 |
All victims |
109 |
137 |
95 |
120 |
115 |
99 |
82 |
100 |
93 |
62 |
Shooting |
2 |
8 |
8 |
8 |
4 |
2 |
2 |
2 |
5 |
1 |
Sharp instrument |
55 |
72 |
34 |
54 |
55 |
57 |
35 |
61 |
47 |
26 |
Blunt instrument |
5 |
8 |
4 |
15 |
8 |
8 |
10 |
8 |
5 |
10 |
Hitting and kicking |
22 |
14 |
25 |
16 |
15 |
10 |
10 |
14 |
13 |
15 |
Strangulation or asphyxiation |
5 |
10 |
4 |
3 |
6 |
5 |
7 |
2 |
1 |
3 |
Drowning |
– |
1 |
– |
1 |
2 |
1 |
– |
2 |
1 |
– |
Fire |
3 |
1 |
3 |
3 |
1 |
3 |
4 |
– |
4 |
– |
Poisoning |
8 |
12 |
9 |
13 |
12 |
8 |
3 |
1 |
3 |
3 |
Other or unknown |
9 |
11 |
8 |
7 |
12 |
5 |
11 |
10 |
14 |
4 |
Table 1. Homicide figures and methods of killing from 2003-2013 (ScotGov, 2013)
Table 1 shows that homicide using a sharp instrument is the most common method, at the highest point in 2010-11 was 61% and at the lowest point in 2005-06 was 35.79%.
Table 2 shows that more than half (58.2%) of the murders committed in Lothian and borders between 2006 and 2011 used a kitchen knife.
Total number of homicides |
55 |
Kitchen knife |
58.2% |
Blunt instrument |
10.9% |
Hitting and kicking |
10.9% |
Strangulation/asphyxiation |
7.3% |
Sharp object (not knife) |
3.6% |
Shooting |
1.8% |
Poisoning |
0% |
Knife unknown type |
0% |
Other knife (not kitchen) |
0% |
Drowning |
0% |
Fire |
0% |
Other |
7.3% |
Table 2. Homicide methods in Lothian and Borders 2006-11, Adapted from (Kidd, Hughes and Crichton, 2013)
Forensic presumptive tests can be used at scenes of crimes for various reasons. They can test to see what a substance might be i.e. drugs, blood. There are various reagents available for use in the presumptive testing for the presence of blood at a crime scene, using varied types of reactions.
Phenolphthalein is the main reagent used in the Kastle-Meyer presumptive test for blood. This test is mainly used one unidentifiable stains, therefore this is used upon visible (patent) samples.
The Kastle-Meyer test is a catalytic method, the phenolphthalein will cause an alkaline solution to turn pink after its oxidation by peroxide when blood is present. According to (Johnston et al., 2008), it will detect blood as dilute as 1 part in 10,000.
There are several false positives for the test and these include according to (Virkler and Lednev, 2009) chemical oxidants and fruit and may also include vegetable peroxidases.
(Garofano et al., 2006), show that the Kastle-Meyer, Phenolphthalein, test is not as sensitive to blood as Luminol, which is stated as detectable to 1 part in 10,000,000.
Leucomalachite Green or LMG is another widely used catalytic method to presumptive test for blood. It works by the same principle as Kastle-Meyer with the exception of the stain being gently rubbed with filter paper containing the reagent. After no colour has developed hydrogen peroxide is again added as in Kastle-Meyer and a green colour change in this case is in indicative of the presence of Blood. Johnston et al, also state that Leucomalachite green has a sensitivity similar to that of Phenolphthalein, 1 part in 10,000.
Luminol is a forensic presumptive test for latent blood, i.e. blood which cannot be seen. Crime scenes are often cleaned afterwards by the perpetrator in an attempt to hide any evidence of what had occurred. Luminol allows crime scene investigators to see the full picture at a cleaned crime scene.
Webb et al, 2006, State that Luminol is known as the most sensitive of the presumptive tests currently used at crime scenes.
According to (Patel and Hopwood, 2013) There are two more commonly used Luminol formulations. These formulations were developed by Grodsky in 1951, Luminol I, and Weber in 1961, Luminol II.
Luminol I or the Grodsky formulation uses a base of sodium carbonate and sodium perborate as the oxidising agent. However Luminol II or the Weber formulation uses a base of sodium hydroxide and hydrogen peroxide as its oxidising agent.
Commercial luminol products have become more readily available in the recent years and brands such as BlueStar and BlueStar Magnum and Lumiscene, have come onto the market. These products offer the advantage of being easier to prepare than the more traditional formulations.
However according to (Quinones et al., 2007) The Grodsky formulation of Luminol I can have a detrimental effect on the ability to subsequently perform DNA analysis in comparison to the Weber and BlueStar alternatives.
Luminol’s sensitivity may be an advantage at finding the smallest drop of blood, but it is also its downfall.
DNA is without doubt the greatest scientific discovery of forensic use to date.
PCR
Akane et al., 1994 investigated the role haem from blood played in interfering with DNA and in inhibiting the polymerase chain reaction. This early study suggested that a haem-blood protein complex caused inhibition issues to the polymerase chain reaction and forwarded the investigations into a more reliable PCR technique.
qPCR or real time polymerase chain reaction,
RFLP or Restriction Fragment Length Polymorphisms
STRs or Short tandem repeats, are genetic markers which were first discovered in the early 1990’s. (Edwards et al., 1992) Showed that STRs were an effective tool when used for human identity testing. They showed that there were enough variation through alleles for individuals to be positively identified.
STR profiling works by comparing sizes of the sample DNA STRs with standardized databased allelic ladders.
New alleles are still being discovered with variations in size which may not be found in commercially available ladders.
(Gill et al., 2000) explain that LCN or low copy number, in a PCR amplification technique which can be applied to DNA samples with as little as <100pg total genomic DNA. It works by increasing the number or amplification cycles the sample undergoes during PCR.
Kloosterman & Kersbergen, 2003, explain that ‘28 + 6’ improved efficacy of DNA sample genotyping. Their 34 cycle PCR technique instead of the normal 28 PCR cycles offered an alternative approach to genotyping forensic DNA samples, which are perhaps low quality or degraded.
Low copy number analysis of DNA is not without problems. The most common issues with LCN are allelic drop-out, heterozygote imbalance, stutter peaks/products and unexpected allelic peaks.
Stutter products
In the US a system known as CODIS is used for DNA profiling. CODIS uses 13 loci and Amelogenin. The loci used are CSF1PO, FGA, TH01, TPOX, VWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11.
The DNA profiling system used in the UK is SGM Plus (SGM+). This system looks at 11 different loci on different chromosomes (independent inheritance) with a large number of alleles. As well as looking at Amelogenin, the sex marker, the SGM+ includes the markers D2S1338 and D19S433 along with eight CODIS overlapping loci FGA, TH01, VWA, D3S1358, D8S1179, D16S539, D18S51, and D21S11.
(Cotton et al., 2000) Validated the most recent 11 loci STR DNA analysis method for use in standard forensic casework. The technique was also validated for use in casework involving > 1ng of DNA, i.e. LCN.
HUMVWFA31/A (vWA)
HUMTHO1 (THO1)
HUMFIBRA (FGA)
If you have committed a crime, disposing or destroying of the evidence is more than likely your next step. More often than not this is problem faced by forensic scientists, that a deliberate attempt to remove any of the biological material i.e. evidence, blood, using a variety of cleaning materials. Most people store their cleaning supplies in their kitchen or bathroom, so general household cleaners are to be examined.
Every household will contain basic cleaning materials such as bleaches, detergents, disinfectants and perhaps multi-cleaners. Cleaning materials not only have the ability to potentially cause contamination to of any of the surviving evidence but also to degrade any DNA which may still be present on the evidence. Degradation of the DNA will make it difficult to produce and gain a profile which could be used to link the weapon to the crime.
Bleaches can cause many problems at crime scenes, thanks to the American television show Crime Scene Investigation (CSI Las Vegas) most people will know that bleach renders the forensic presumptive blood tests pretty much useless. According to (Harris et al., 2006), Out of all the cleaning products on the market bleach also has the most harmful effect on the quality of DNA available to obtain a profile. They also state that bleach seemed to cause continued degradation of the DNA over time. Common brands of household bleaches include Domestos, Harpic, Mr Muscle, Cif and Supermarket own brands.
Common brands of household detergents include Fairy, Imperial leather, Carex, Daz and Bold.
Common brands of household anti-bacterial disinfectant include Dettol, Savlon, TCP and supermarket own brands.
This study aims to investigate whether the knife substrate has any effect on the quantity of DNA retained on the weapon after an assault; whether deliberate attempts to remove any biological material, using a variety of household cleaning materials, affect the quality and quantity of DNA that is recoverable and if DNA is recovered from a weapon, whether it was initially detected by presumptive blood tests.
The knife substrates used here were, 18” Kitchen knife and 20” Serrated kitchen knife.
The household cleaning materials were as follows, Bleach (Domestos), Detergent (Fairy) and Anti-Bacterial disinfectant (Dettol).
Blood samples are to be applied to the blade of each knife, it should be allowed to air dry and then cleaned until no blood or residues thereof are visible. Each knife should then again be allowed to air dry and be swabbed using a double swab technique.
Each cleaning material is applied to the two different knife substrates and the pairs are numbered 3-18, with knife set 1 & 2 being control, the initial DNA for comparison should be swabbed before the control knifes are dried and washed with warm water only. Cleaning materials should be used according to the manufacturers’ guidelines.
PCR will be performed on the extracted samples using
The control samples will be used to examine which was the largest contributing factor in compromising the quality and/or quantity of the sample gained.
The Scottish Government, (2013) Statistical Bulletin, Homicide in Scotland 2012-13, {Online} Available: https://alpha.scotland.gov.uk/government/uploads/system/uploads/attachment_data/file/417/Homicide_in_Scotland_2012-13_statistical_bulletin.pdf [Accessed: 02/10/2014]
Cotton, E. A., Allsop, R. F., Guest, J. L., Frazier, R. R., Koumi, P., Callow, I. P., Seager, A., and Sparkes, R. L. (2000) Validation of the AMPFlSTR SGM plus system for use in forensic casework. Forensic Sci Int. Vol.112(2-3), pp.151-61.
Edwards, A., Hammond, H. A., Jin, L., Caskey, C. T., and Chakraborty, R. (1992) Genetic variation at five trimeric and tetrameric tandem repeat loci in four human population groups. Genomics. Vol.12(2), pp.241-53.
Garofano, L., Pizzamiglio, M., Marino, A., Brighenti, A., and Romani, F. (2006) A comparative study of the sensitivity and specifity of luminal and fluorescein on diluted and aged bloodstains and subsequent STRs typing. International Congress Series. Vol.1288(0), pp.657-659.
Gill, P., Whitaker, J., Flaxman, C., Brown, N., and Buckleton, J. (2000) An investigation of the rigor of interpretation rules for STRs derived from less than 100 pg of DNA. Forensic Sci Int. Vol.112(1), pp.17-40.
Harris, K. A., Thacker, C. R., Ballard, D., and Court, D. S. (2006) The effect of cleaning agents on the DNA analysis of blood stains deposited on different substrates. International Congress Series. Vol.1288(0), pp.589-591.
Johnston, E., Ames, C. E., Dagnall, K. E., Foster, J., and Daniel, B. E. (2008) Comparison of presumptive blood test kits including hexagon OBTI. J Forensic Sci. Vol.53(3), pp.687-9.
Kidd, S., Hughes, N., and Crichton, J. (2013) Kitchen knives and homicide: A systematic study of people charged with murder in the Lothian and Borders region of Scotland. Med Sci Law. Vol.54(3), pp.167-173.
Patel, G., and Hopwood, A. (2013) An evaluation of luminol formulations and their effect on DNA profiling. Int J Legal Med. Vol.127(4), pp.723-9.
Quinones, I., Sheppard, D., Harbison, S., and Elliot, D. (2007) Comparative Analysis of Luminol Formulations. Canadian Society of Forensic Science Journal. Vol.40(2), pp.53-63.
Virkler, K., and Lednev, I. K. (2009) Analysis of body fluids for forensic purposes: From laboratory testing to non-destructive rapid confirmatory identification at a crime scene. Forensic Science International. Vol.188(1–3), pp.1-17.
You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.
Read moreEach paper is composed from scratch, according to your instructions. It is then checked by our plagiarism-detection software. There is no gap where plagiarism could squeeze in.
Read moreThanks to our free revisions, there is no way for you to be unsatisfied. We will work on your paper until you are completely happy with the result.
Read moreYour email is safe, as we store it according to international data protection rules. Your bank details are secure, as we use only reliable payment systems.
Read moreBy sending us your money, you buy the service we provide. Check out our terms and conditions if you prefer business talks to be laid out in official language.
Read more